Features
- High accuracy, ± 0.5% ratio error, Phase shift error < 0.3%
- High linearity, large measurement range capacity (6000A or greater)
- High sensitivity, accuracy down to 50A
- Next Generation Design has less positional error
- High immunity to EMI and magnetic fields
- Ideal for use with WattsOn-Mark II Advanced Energy Meter
- Ideal for use with i-Spy Advanced 3-Phase AC Current Monitor
Product Description
The RC-600 is a flexible, air-core current sensor which operates on the Rogowski Coil principle. The RC-600 is designed and approved to be installed on insulated and/or bare conductors (bus bars).
The unique shielding system and precision windings minimize the positioning error and practically eliminate the influence of external magnetic fields.
The RC-600 can be used directly with the WattsOn-Mark II Precision Energy Meters without an integrator or additional power supply. This offers accurate measurements in large power systems where conventional iron-core CTs may be hard to install.
Each RC-600 coil has a unique serial number and is factory calibrated. Three identical coils are shipped with one meter for best accuracy.
Installation Examples
Specifications
Coil Length | 600 mm (23.6"); allows for a 7.5" diameter wire window | ||
Coil Diameter | Coil diameter 8.3 mm (0.32") | ||
Output | 100mV/1000A (50Hz) 120mV/1000A (60Hz) | ||
Output Waveform | AC voltage proportional to derivative of input current Requires integrator for measurement of AC current (built into WattsOn-Mark II) | ||
Outer sheath | Thermoplastic polyurethane UL94-V0 | ||
Leads | Shielded pair AWG22, 3 m (9ft 8") AWM style 21223, 1000V, 80°C | ||
Insulation Class | 1000V; 50-60 Hz, Cat III, 600V, 50-60Hz, CAT IV | ||
Test Voltage | 7400 Vrms for 1 min | ||
Maximum measured current | 100,000A @50Hz | ||
Ratio error | <0.5% of reading | ||
Phase shift error | < 0.3% | ||
Linearity | 0.1 % | ||
Positioning error | One Loop: < 1% of reading with a 15 mm wire Two loops: less than 0.3% | ||
Certification | UL Recognized (Canada/USA) |